3-36
Fill Valve (shown removed for clarity)
Figure 3-17
3. Turn on the fill control switch at the helm.
4. Adjust the fill valve inside the livewell for desired
water flow.
Troubleshooting the Livewell Fill System
Livewell Does Not Fill
If livewell will not fill and the pump is operating:
Check the transom drains to determine that they
are free of debris.
Check the “valve” inside the livewell to ensure that
it is in the OPEN position.
Check for airlock, using the main engine; reverse
the boat to force water into the transom inlet and
pump. This will help determine if the pump is “air
locked.” If the pump was “air locked,” water should
now begin to flow into the livewell. If the pump
remains “air locked,” check fill hose routing for
kinks or excessive loops.