3-40
2. Position the RECIRC button on the helm in the ON
position.
3. Ensure the FILL button on the helm is OFF.
During livewell pump-out operation, water will be
discharged through the pump-out rear deck fitting.
Manual Drain
To completely drain the water from the livewell using
the gravity drain while the boat is “ON” or “OFF
PLANE” or while on the boat is on the trailer:
1. Open the livewell actuator valve.
2. Position the RECIRC button on the helm to OFF.
3. Ensure the FILL button on the helm is OFF.
NOTE: When off plane at a rest position in the
water, the livewell will only drain to a level
that is equal to the water surrounding the
boat.
Troubleshooting the Livewell Drain System
If the livewell will not drain, verify the following:
The actuator is in the OPEN position.
The livewell drain screen is not clogged.
If the livewell will not pump out, verify the following:
The “pump-out valve” in the livewell is pulled OUT.
The RECIRC button on the helm is ON and the
RECIRC pump is ON.
NOTE: To determine if the pump is operating, place
your hand on the pump. A slight vibration
will be felt if the pump is operating.
Remove pump cartridge and inspect pump housing.
Check battery.
Check pump fuse.
Electric Trolling Motor
See the electric trolling motor Operator’s Manual
supplied in your owner’s kit for electric trolling motor
operation and maintenance procedures.