Day: When the system is not armed a Day zone will cause an Extended Monitor
activation and can send a Day Zone Trouble report to the central station. When the
system is armed a Day Zone will act like an Exterior Instant. A day zone extended
monitor activation can be cancelled with the "Silence Day Zone" button function.
Emergency: Emergency zones respond though inside speakers only. The alert consists
of a pulsed tone followed by "ALERT, ALERT", and the up-to-four-word description of the
zone.
Exterior Instant: Exterior instant zones instantly sound an alarm when the system is
armed to HOME, AWAY or NIGHT. When the system is not armed, monitor mode is
active, and the zone is programmed to show open/close status at the keypad, the system
will speak the zone description or sound a monitor beep when the zone input is
activated. Exterior Instant zones can be programmed to sound an alarm when the input
is activated during an exit delay (System Options - Group 2, option 008). Otherwise, the
exterior instant zone will respond in the same manner as when the system is not armed.
Exterior Delay #1: Tripping an exterior delay input places the system into a pre-alarm
mode if the system is armed to AWAY or HOME (unless "No entry delay for Exterior
Delay #1 in Home" is selected in System Options - group 2). The system refers to entry
delay time #1 to determine the pre-alarm duration. If pre-alarm expires without a user
entering a valid disarm code, the system will sound an alarm. When the system is not
armed, monitor mode is active, and the zone is programmed to show open/close status at
keypad, the system will speak the zone description or sound a monitor beep when the
zone input is activated. During an exit delay, Exterior Delay zones respond in the same
manner as when the system is not armed. In Night mode, this zone type acts an exterior
instant.
Exterior Delay #2: Same as above but uses programmable entry delay time #2.
Fire: Fire zones respond with short high volume tones over the internal and external
speakers. The system will alternate between the tones and speaking "FIRE, FIRE,"
followed by the up-to-four-word zone description, and "REMAIN CALM, LEAVE
IMMEDIATELY."
Follower: An interior follower zone is active in the AWAY mode only. A follower acts
as an instant zone providing an exterior delay zone is not previously tripped. When the
system is in pre-alarm, the follower follows the pre-alarm time. No monitor function is
provided and during an exit delay, an opening is ignored.
Interior Instant: The interior instant zones are active in the AWAY mode only. No
monitor function is provided for interior zones (except during extended monitor). During
an exit delay, an opening is ignored.
Interior Delay #1: Same as Exterior Delay #1 except active only in AWAY mode and no
monitor is provided.
Interior Delay #2: Same as Exterior Delay #2 except active only in AWAY and NIGHT
mode and no monitor is provided. Uses delay time #2.
Panic: Panic zones respond with a high volume alert on both the internal and external
speaker. The alert consists of a pulsed tone followed by "ALERT, ALERT", and the up-to-
four-word description of the zone.